For daily operating concrete pump truck, what
attention that we should pay to so that can ensure
using the concrete pump truck safe and longthen
the service life of concrete boom pump? Let’s see
the tips as follows:
1. The concrete pump truck should be parked on a
flat and solid place. The bottom of the outrigger
should be stabilized by a skid support, and there
should be no obstacles within the rotation range
of the boom. It is strictly forbidden to work under
high voltage transmission lines.2. Check before operation to confirm safety.
(1) The stirring mechanism works normally, and
the transmission mechanism should act
accurately;
(2) The cracks, damage, deformation and wear of
the conveying pipe should be within the specified
range;
(3) The pipe connection should be well sealed;
(4) The hopper screen is in good condition;
(5) The hydraulic system should work normally;
(6) Instruments and signal indicators are complete
and intact, various and dynamic valves are flexible
and reliable in positioning.
3. It is strictly forbidden to connect long conveying pipes and hoses during operation. The hose must not be dragged on the ground.
4. The boom should be opened in strict order during the operation. It is strictly forbidden to operate when the wind is greater than level 6 (including level 6).
5. It is strictly forbidden to use the boom as a lifting tool.
6. During the pumping operation, the operator
should pay attention to observe the construction
work area and the working status of the
equipment. No one should stay within the working
range of the boom.7. It is strictly forbidden to pull the hydraulic
outrigger control valve during operation. If it is
found that the car body is inclined or other
abnormal phenomena, the operation should be
stopped immediately, the boom should be
retracted for inspection, and the operation should
be continued after the fault is eliminated.
8. During pumping operation, it is strictly forbidden to cross the mixing hopper
9. When removing the blockage of the pipeline,
the surrounding personnel should be evacuated.
Before dismantling management and cleaning, a
back-pumping method should be adopted to
eliminate the pressure in the conveying pipeline.
When dismantling, it is strictly forbidden to face
people.10. Do not remove the hopper grille and other
installation devices during operation. Do not climb and ride on the delivery pipeline, and do not
stretch the handle into the valve body. It is strictly
forbidden to disassemble the pipeline when
pumping.
11. When cleaning the pipeline, the operator should leave the outlet of the pipeline and the elbow joint. If the pipeline is cleaned with compressed air, there shall be no personnel and equipment within 10m of the pipeline outlet.